플럭스 코어드 아크 용접
★ flux-cored arc welding 플럭스 코어드 아크 용접.
Flux-Cored Arc Welding This arc-welding process was developed in the early 1950s as an adaptation of shielded metal arc welding to overcome the limitations imposed by the use of stick electrodes. Flux-cored arc welding (FCAW) is an arcwelding process in which the electrode is a continuous consumable tubing that contains flux and other ingredients in its core. Other ingredients may include deoxidizers and alloying elements. The tubular fl ux-cored “wire” is fl exible and can therefore be supplied in the form of coils to be continuously fed through the arc-welding gun. There are two versions of FCAW: (1) self-shielded and (2) gas shielded. In the first version of FCAW to be developed, arc shielding was provided by a fl ux core, thus
leading to the name self-shielded fl ux-cored arc welding. The core in this form of FCAW includes not only fl uxes but also ingredients that generate shielding gases for protecting the arc. The second version of FCAW, developed primarily for welding steels, obtains arc shielding from externally supplied gases, similar to gas metal arc welding. This version is called gas-shielded fl ux-cored arc welding. Because it utilizes an electrode containing its own fl ux together with separate shielding gases, it might be considered a hybrid of SMAW and GMAW. Shielding gases typically employed are carbon dioxide for mild steels or mixtures of argon and carbon dioxide for stainless steels. Figure 29.6 illustrates the FCAW process, with the gas optional) distinguishing between the two types.
leading to the name self-shielded fl ux-cored arc welding. The core in this form of FCAW includes not only fl uxes but also ingredients that generate shielding gases for protecting the arc. The second version of FCAW, developed primarily for welding steels, obtains arc shielding from externally supplied gases, similar to gas metal arc welding. This version is called gas-shielded fl ux-cored arc welding. Because it utilizes an electrode containing its own fl ux together with separate shielding gases, it might be considered a hybrid of SMAW and GMAW. Shielding gases typically employed are carbon dioxide for mild steels or mixtures of argon and carbon dioxide for stainless steels. Figure 29.6 illustrates the FCAW process, with the gas optional) distinguishing between the two types.

[출처: Mikell P. Groover, Fundamentals of Modern Manufacturing Materials, Processes, and Systems]